CG610 General Fluid Loss Additive

It is applicable to conventional density, low density and high density cement slurry systems, used in medium and high temperature well conditions (≤180℃).
It has good salt resistance and excellent water loss reduction performance in saturated salt water cement slurry systems.

CG610 General Fluid Loss Additive

Select the number of specifications

Please check the product information you want!

Instructions MSDS

SUMMARY

  • CG610 fluid loss additive is a synthetic polymer which is capable of effectively reducing water loss filtering from the slurry to porous formation during cementing process.
  • Applicable for medium and high temperature wells.
  • Control fluid loss in lightweight, normal density or high density cement slurries.
  • Applicable mixing water: from fresh water to salt-saturated water.
  • Used below temperature of 204.4℃ (400℉, BHCT).
  • Compatible well with other additives.
  • CG610 series contains of L-type liquid, L-A type anti-freezing liquid and S-P type powder.
  • Recommended dosage is 2.0-6.0(BWOC) for liquid products, and 0.6-2.5% (BWOC) for powder product.


PHYSICAL AND CHEMICAL INDICATORS

CG610S-P

CG610L

Appearance:White or faint yellow powder

Appearance:Colorless or faint yellow liquid

Bulk Density, g/cm3: 0.80±0.20

Density, g/cm3: 1.10±0.05(L), 1.15±0.05(L-A)

Water-Solubility: Soluble

Water-Solubility: Soluble


CEMENT SLURRY PERFORMANCE

Item

Test Condition

Technical Indicator

Density of the cement slurry, g/cm3

25℃, Atmospheric Pressure

1.90±0.01

Fluid loss, ml

Fresh water system

80℃,6.9MPa

≤50

120℃,6.9MPa

≤50

18% salt water system

90℃,6.9MPa

≤150

Thickening performance

Initial consistency, Bc

80℃/45min,46.5MPa

≤30

40-100 Bc thickening time, min

≤40

Free fluid, %

80℃, Atmospheric Pressure

≤1.4

24h compressive strength, MPa

≥14


STANDARD PACKAGING AND STORAGE                                                                                                                

  • The liquid type products should be used within 12 months after production. Packed in 25kg, 200L and 5 US gallon plastic barrels. The powder type products should be used within 24 months after production. Packed in25kg bag.
  • Customized packages are also available.
  • Once expired, it shall be tested before use.

 

 

Keiloil·Global Factory-www.kelioil.com/en


Click here to download MSDS

SECTION 1: PRODUCT NAME

PRODUCT NAME: CG610 Cementing Fluid loss additive

SECTION 2: HAZARDS IDENTIFICATION

CHARACTERISTICS: Nonflammable and inexplosive.

HEALTH HAZARDS: Irritate eye and skin slightly; Cause irritation of the mucosal and upper respiratory tract.

ENVIROMENTAL HAZARDS: Slightly toxic to fish and animal.

SPECIAL ATTENTION: None.

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS

Type

INGREDIENT NAME

COMPOSITION

CAS NO.

CG610L

Copolymer

16-30%

/

Water

70-84%

7732-18-5

CG610S-P

Copolymer

98%

/

Water

2%

7732-18-5

SECTION 4: FIRST AID MEASURES

SKIN CONTACT: Put off contaminated clothing, rinse with soapy and clean flowing water.

EYE CONTACT: Raise the eyelid. Rinse it with plenty of clean flowing water and physiological saline. Consult a doctor if irritation occurs.

INGESTION: Drink plenty of water to induce vomiting; If be uncomfortable, consult a doctor please.

INHALATION: Escape to fresh air; If have breathing difficulties, consult a doctor.

SPECIAL ATTENTION: None.

SECTION 5: FIRE-FIGHTING MEASURES

FLAMMABILITY: See section 9(Physical and Chemical Properties).

FIRE FIGHTING MEDIUM: Foam, dry powder, carbon dioxide, water.  

SPECIAL FIRE-FIGHTING EQUIPMENTS: None.

SECTION 6: ACCIDENTAL RELEASE MEASURES

PERSONAL PRECATIONALS: Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection).

SPILL: Collect the most of leakage, clean the site of leakage.

WASTE TREATMENT METHODS: Be properly buried or handled according to local environment requirement.

PACKING TREATMENT METHODS: Transferred to the dumping site for proper disposal.

SECTION 7: HANDLING AND STORAGE

HANDLING: Keep the containers closed when not in use. Do not get in eyes, on skin. Wear proper personal protection.

STORAGE ATTENTION: Stored in a dry cool place, prevented from the sun and rain, kept away from the heat and fire and incompatible materials.

SPECIAL ATTENTION: None.

SECTION 8: ESPOSURE CONTROLS AND PERSONAL PROTECTION

ENGINEERING CONTROL: Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors or particles below their respective threshold limit value.

RESPIRATORY PROTECTION: Wear dusk mask.

SKIN PROTECTION: Wear standard protective clothing and gloves.

EYE PROTECTION: Wear chemical splash goggles.

SPECIAL ATTENTION: Smoking, food and water drinking are all forbidden. 

SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES

Item

CG610L-A

CG610S-P

COLOR

White or faint yellow

White or faint yellow

PHYSICAL STATE

Liquid

powder

RELATIVE DENSITY(water equal to 1)

Standard type1.10±0.05

Anti-freeze type1.15±0.05

——

BULK DENSITY, g/cm3

——

0.80±0.20

ODOR

Slightly pungent

Slightly pungent

WATER SOLUBILITY

Soluble in water

Soluble in water

SECTION 10: STABILITY AND REACTIVITY

AVIOD: Open fire, High temperature.

INCOMPATIBLE MATERIAL: Strong oxidizers.

HAZARDOUS DECOMPOSITION PRODUCTS: None.

SECTION 11: TOXICOLOGICAL INFORMATION

INVASIVE ROUTE: Accidental inhalation or ingestion.

HEALTH HAZARD: Careless ingestion has a stimulating effect on the oral cavity and stomach.

SKIN CONTACT: Contact with skin for a long time, slightly induce skin redness.

EYE CONTACT: Induce eye irritant.

INGESTION: Lead to nausea and vomiting.

INHALATION: Lead to cough and prickle.

CARCINOGENICITY: None.

SPECIAL REMIND: None.

SECTION 12: ECOLOGICAL INFORMATION

BIODEGRADABLE: Not available.

ECOTOXICITY: Not available.

SECTION 13: DISPOSAL CONSIDERATIONS

WASTE TREATMENT METHOD: Be properly buried or handled according to local environment requirement.

PACKING TREATMENT METHOD: Transferred to the dumping site for proper disposal.

SECTION 14: TRANSPORT INFORMATION

This product is not included in the dangerous goods transport international regulations(IMDG,IATA,ADR/RID)

PACKAGE       Liquid-Plastic barrel, Powder-bag.

SECTION 15: REGULATORY INFORMATION

The Management Regulations of Dangerous Chemicals Management

The Practical Detailed Rules and Regulation for Dangerous Chemicals Management

The Classification and mark of Common Chemical Products (GB 13690-2009)

The General Rule of Common Chemical Products (GB15603-1995)

The Technology Conditions for the Packing Marks for Hazardous Cargo (GB 12463 -1990)

SECTION 16: OTHER INFORMATION

RELEASE DATE: 05/08/2003.

REVISION DATE: 10/14/2022.

SUGGEST FOR AND USED RESTRICTIONS: The product is to be used in applications consistent with our product literature. This product is applied to industry only.

 

 


No comment

Instructions

SUMMARY

  • CG610 fluid loss additive is a synthetic polymer which is capable of effectively reducing water loss filtering from the slurry to porous formation during cementing process.
  • Applicable for medium and high temperature wells.
  • Control fluid loss in lightweight, normal density or high density cement slurries.
  • Applicable mixing water: from fresh water to salt-saturated water.
  • Used below temperature of 204.4℃ (400℉, BHCT).
  • Compatible well with other additives.
  • CG610 series contains of L-type liquid, L-A type anti-freezing liquid and S-P type powder.
  • Recommended dosage is 2.0-6.0(BWOC) for liquid products, and 0.6-2.5% (BWOC) for powder product.


PHYSICAL AND CHEMICAL INDICATORS

CG610S-P

CG610L

Appearance:White or faint yellow powder

Appearance:Colorless or faint yellow liquid

Bulk Density, g/cm3: 0.80±0.20

Density, g/cm3: 1.10±0.05(L), 1.15±0.05(L-A)

Water-Solubility: Soluble

Water-Solubility: Soluble


CEMENT SLURRY PERFORMANCE

Item

Test Condition

Technical Indicator

Density of the cement slurry, g/cm3

25℃, Atmospheric Pressure

1.90±0.01

Fluid loss, ml

Fresh water system

80℃,6.9MPa

≤50

120℃,6.9MPa

≤50

18% salt water system

90℃,6.9MPa

≤150

Thickening performance

Initial consistency, Bc

80℃/45min,46.5MPa

≤30

40-100 Bc thickening time, min

≤40

Free fluid, %

80℃, Atmospheric Pressure

≤1.4

24h compressive strength, MPa

≥14


STANDARD PACKAGING AND STORAGE                                                                                                                

  • The liquid type products should be used within 12 months after production. Packed in 25kg, 200L and 5 US gallon plastic barrels. The powder type products should be used within 24 months after production. Packed in25kg bag.
  • Customized packages are also available.
  • Once expired, it shall be tested before use.

 

 

Keiloil·Global Factory-www.kelioil.com/en


MSDS

Click here to download MSDS

SECTION 1: PRODUCT NAME

PRODUCT NAME: CG610 Cementing Fluid loss additive

SECTION 2: HAZARDS IDENTIFICATION

CHARACTERISTICS: Nonflammable and inexplosive.

HEALTH HAZARDS: Irritate eye and skin slightly; Cause irritation of the mucosal and upper respiratory tract.

ENVIROMENTAL HAZARDS: Slightly toxic to fish and animal.

SPECIAL ATTENTION: None.

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS

Type

INGREDIENT NAME

COMPOSITION

CAS NO.

CG610L

Copolymer

16-30%

/

Water

70-84%

7732-18-5

CG610S-P

Copolymer

98%

/

Water

2%

7732-18-5

SECTION 4: FIRST AID MEASURES

SKIN CONTACT: Put off contaminated clothing, rinse with soapy and clean flowing water.

EYE CONTACT: Raise the eyelid. Rinse it with plenty of clean flowing water and physiological saline. Consult a doctor if irritation occurs.

INGESTION: Drink plenty of water to induce vomiting; If be uncomfortable, consult a doctor please.

INHALATION: Escape to fresh air; If have breathing difficulties, consult a doctor.

SPECIAL ATTENTION: None.

SECTION 5: FIRE-FIGHTING MEASURES

FLAMMABILITY: See section 9(Physical and Chemical Properties).

FIRE FIGHTING MEDIUM: Foam, dry powder, carbon dioxide, water.  

SPECIAL FIRE-FIGHTING EQUIPMENTS: None.

SECTION 6: ACCIDENTAL RELEASE MEASURES

PERSONAL PRECATIONALS: Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection).

SPILL: Collect the most of leakage, clean the site of leakage.

WASTE TREATMENT METHODS: Be properly buried or handled according to local environment requirement.

PACKING TREATMENT METHODS: Transferred to the dumping site for proper disposal.

SECTION 7: HANDLING AND STORAGE

HANDLING: Keep the containers closed when not in use. Do not get in eyes, on skin. Wear proper personal protection.

STORAGE ATTENTION: Stored in a dry cool place, prevented from the sun and rain, kept away from the heat and fire and incompatible materials.

SPECIAL ATTENTION: None.

SECTION 8: ESPOSURE CONTROLS AND PERSONAL PROTECTION

ENGINEERING CONTROL: Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors or particles below their respective threshold limit value.

RESPIRATORY PROTECTION: Wear dusk mask.

SKIN PROTECTION: Wear standard protective clothing and gloves.

EYE PROTECTION: Wear chemical splash goggles.

SPECIAL ATTENTION: Smoking, food and water drinking are all forbidden. 

SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES

Item

CG610L-A

CG610S-P

COLOR

White or faint yellow

White or faint yellow

PHYSICAL STATE

Liquid

powder

RELATIVE DENSITY(water equal to 1)

Standard type1.10±0.05

Anti-freeze type1.15±0.05

——

BULK DENSITY, g/cm3

——

0.80±0.20

ODOR

Slightly pungent

Slightly pungent

WATER SOLUBILITY

Soluble in water

Soluble in water

SECTION 10: STABILITY AND REACTIVITY

AVIOD: Open fire, High temperature.

INCOMPATIBLE MATERIAL: Strong oxidizers.

HAZARDOUS DECOMPOSITION PRODUCTS: None.

SECTION 11: TOXICOLOGICAL INFORMATION

INVASIVE ROUTE: Accidental inhalation or ingestion.

HEALTH HAZARD: Careless ingestion has a stimulating effect on the oral cavity and stomach.

SKIN CONTACT: Contact with skin for a long time, slightly induce skin redness.

EYE CONTACT: Induce eye irritant.

INGESTION: Lead to nausea and vomiting.

INHALATION: Lead to cough and prickle.

CARCINOGENICITY: None.

SPECIAL REMIND: None.

SECTION 12: ECOLOGICAL INFORMATION

BIODEGRADABLE: Not available.

ECOTOXICITY: Not available.

SECTION 13: DISPOSAL CONSIDERATIONS

WASTE TREATMENT METHOD: Be properly buried or handled according to local environment requirement.

PACKING TREATMENT METHOD: Transferred to the dumping site for proper disposal.

SECTION 14: TRANSPORT INFORMATION

This product is not included in the dangerous goods transport international regulations(IMDG,IATA,ADR/RID)

PACKAGE       Liquid-Plastic barrel, Powder-bag.

SECTION 15: REGULATORY INFORMATION

The Management Regulations of Dangerous Chemicals Management

The Practical Detailed Rules and Regulation for Dangerous Chemicals Management

The Classification and mark of Common Chemical Products (GB 13690-2009)

The General Rule of Common Chemical Products (GB15603-1995)

The Technology Conditions for the Packing Marks for Hazardous Cargo (GB 12463 -1990)

SECTION 16: OTHER INFORMATION

RELEASE DATE: 05/08/2003.

REVISION DATE: 10/14/2022.

SUGGEST FOR AND USED RESTRICTIONS: The product is to be used in applications consistent with our product literature. This product is applied to industry only.

 

 


CG610 General Fluid Loss Additive
It is applicable to conventional density, low density and high density cement slurry systems, used in medium and high temperature well conditions (≤180℃).
It has good salt resistance and excellent water loss reduction performance in saturated salt water cement slurry systems.
Long press to look detail
Long by picture save/share

CG610 General Fluid Loss Additive

INQUIRY

在线询盘 MORE+
  • 联系人 *

  • 手机 *

  • 描述

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully
请双击输入内容...

Related Products

Leave Us a Message

Fill blanks to contact our sales team.

  • Company Name

  • Name

  • Mobile

  • E-mail *

  • Verification Code

  • Message

  • Send

  • Security Code
    Refresh the code
    Cancel
    Confirm
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了