CG212 Anti-settling Fluid Loss Additives

CG212 is suitable for low-density or conventional-density cement slurry systems with strong dispersibility, especially for 1.2~1.6g/cm³ low-density cement slurry.
It has a significant thickening effect on cement slurry, effectively enhancing the suspension stability of the cement slurry system and preventing sedimentation.
The low-density cement slurry system has good thickening performance and good cement stone strength development.

CG212 Anti-settling Fluid Loss Additives

Select the number of specifications

Please check the product information you want!

Instructions MSDS

SUMMARY

  • CG212 fluid loss additive is a synthetic polymer which is capable of effectively reducing water loss filtering from the slurry to porous formation during cementing process.
  • Specially designed for lightweight cement slurry system and normal density cement slurry with strong dispersity.
  • Generate thickening effect on cement slurry, enhance its suspension stability and prevent sedimentation.
  • The lightweight cement slurries applied with FLA CG212 products exhibit good thickening performance. 
  • Fast compressive strength development of set cement.
  • Applicable mixing water: from fresh water to half-saturated salt water.
  • Used below temperature of 180℃(356℉, BHCT).
  • Compatible with other additives.
  • CG212 series contains of L-type liquid, L-A type anti-freezing liquid and S-P type powder.
  • Recommended dosage is 2.0-6.0 (BWOC) for liquid products, and 0.6-2.5% (BWOC) for powder product.

 

PHYSICAL AND CHEMICAL INDICATORS

CG212S-P

CG212L

Appearance:White or faint yellow powder

Appearance:Colorless or faint yellow liquid

Bulk Density, g/cm3: 0.80±0.20

Density, g/cm3: 1.10±0.05(L), 1.15±0.05(L-A)

Water-Solubility: Soluble

Water-Solubility: Soluble


CEMENT SLURRY PERFORMANCE 

Item

Test Condition

Technical Indicator

Density of the lightweight cement slurry, g/cm3

25℃, Atmospheric Pressure

1.35±0.01

Fluid loss,ml

Fresh water system

80℃,6.9MPa

≤80

Thickening performance

Initial consistency, Bc

80℃/45min,46.5MPa

≤30

40-100 Bc thickening time, min

≤40

Free fluid, %

80℃, Atmospheric Pressure

≤1.4

24h compressive strength, MPa

Lightweight cement slurry

≥5.0


PACKING AND STORAGE

  • The liquid type products should be used within 12 months after production. Packed in 25kg, 200L and 5 US gallon plastic barrels.The powder type products should be used within 24 months after production. Packed in25kg bag.
  • Customized packages are also available.
  • Once expired, it shall be tested before use.


                 Keiloil·Global Factory-www.kelioil.com/en

Click here to download MSDS

SECTION 1: PRODUCT NAME

PRODUCT NAME: CG212 Cementing Fluid loss additive

SECTION 2: HAZARDS IDENTIFICATION

CHARACTERISTICS: Nonflammable and inexplosive.

HEALTH HAZARDS: Irritate eye and skin slightly; Cause irritation of the mucosal and upper respiratory tract.

ENVIROMENTAL HAZARDS: Slightly toxic to fish and animal.

SPECIAL ATTENTION: None.

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS

Type

INGREDIENT NAME

COMPOSITION

CAS NO.

CG212L

Copolymer

20-30%

/

Water

70-80%

7732-18-5

CG212S-P

Copolymer

98%

/

Water

2%

7732-18-5

SECTION 4: FIRST AID MEASURES

SKIN CONTACT: Put off contaminated clothing, rinse with soapy and clean flowing water.

EYE CONTACT: Raise the eyelid. Rinse it with plenty of clean flowing water and physiological saline. Consult a doctor if irritation occurs.

INGESTION: Drink plenty of water to induce vomiting; If be uncomfortable, consult a doctor please.

INHALATION: Escape to fresh air; If have breathing difficulties, consult a doctor.

SPECIAL ATTENTION: None.

SECTION 5: FIRE-FIGHTING MEASURES

FLAMMABILITY: See section 9(Physical and Chemical Properties).

FIRE FIGHTING MEDIUM: Foam, dry powder, carbon dioxide, water.  

SPECIAL FIRE-FIGHTING EQUIPMENTS: None.

SECTION 6: ACCIDENTAL RELEASE MEASURES

PERSONAL PRECATIONALS: Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection).

SPILL: Collect the most of leakage, clean the site of leakage.

WASTE TREATMENT METHODS: Be properly buried or handled according to local environment requirement.

PACKING TREATMENT METHODS: Transferred to the dumping site for proper disposal.

SECTION 7: HANDLING AND STORAGE

HANDLING: Keep the containers closed when not in use. Do not get in eyes, on skin. Wear proper personal protection.

STORAGE ATTENTION: Stored in a dry cool place, prevented from the sun and rain, kept away from the heat and fire and incompatible materials.

SPECIAL ATTENTION: None.

SECTION 8: ESPOSURE CONTROLS AND PERSONAL PROTECTION

ENGINEERING CONTROL: Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors or particles below their respective threshold limit value.

RESPIRATORY PROTECTION: Wear dusk mask.

SKIN PROTECTION: Wear standard protective clothing and gloves.

EYE PROTECTION: Wear chemical splash goggles.

SPECIAL ATTENTION: Smoking, food and water drinking are all forbidden. 

SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES

Item

CG212L-A

CG212S-P

COLOR

White or faint yellow

White or faint yellow

PHYSICAL STATE

Liquid

powder

RELATIVE DENSITY(water equal to 1)

Standard type1.10±0.05

Anti-freeze type1.15±0.05

——

BULK DENSITY, g/cm3

——

0.80±0.20

ODOR

Slightly pungent

Slightly pungent

WATER SOLUBILITY

Soluble in water

Soluble in water

SECTION 10: STABILITY AND REACTIVITY

AVIOD: Open fire, High temperature.

INCOMPATIBLE MATERIAL: Strong oxidizers.

HAZARDOUS DECOMPOSITION PRODUCTS: None.

SECTION 11: TOXICOLOGICAL INFORMATION

INVASIVE ROUTE: Accidental inhalation or ingestion.

HEALTH HAZARD: Careless ingestion has a stimulating effect on the oral cavity and stomach.

SKIN CONTACT: Contact with skin for a long time, slightly induce skin redness.

EYE CONTACT: Induce eye irritant.

INGESTION: Lead to nausea and vomiting.

INHALATION: Lead to cough and prickle.

CARCINOGENICITY: None.

SPECIAL REMIND: None.

SECTION 12: ECOLOGICAL INFORMATION

BIODEGRADABLE: Not available.

ECOTOXICITY: Not available.

SECTION 13: DISPOSAL CONSIDERATIONS

WASTE TREATMENT METHOD: Be properly buried or handled according to local environment requirement.

PACKING TREATMENT METHOD: Transferred to the dumping site for proper disposal.

SECTION 14: TRANSPORT INFORMATION

This product is not included in the dangerous goods transport international regulations(IMDG,IATA,ADR/RID)

PACKAGE       Liquid-Plastic barrel, Powder-bag.

SECTION 15: REGULATORY INFORMATION

The Management Regulations of Dangerous Chemicals Management

The Practical Detailed Rules and Regulation for Dangerous Chemicals Management

The Classification and mark of Common Chemical Products (GB 13690-2009)

The General Rule of Common Chemical Products (GB15603-1995)

The Technology Conditions for the Packing Marks for Hazardous Cargo (GB 12463 -1990)

SECTION 16: OTHER INFORMATION

RELEASE DATE: 12/18/2014.

REVISION DATE: 10/14/2022.

SUGGEST FOR AND USED RESTRICTIONS: The product is to be used in applications consistent with our product literature. This product is applied to industry only.

 

 


No comment

Instructions

SUMMARY

  • CG212 fluid loss additive is a synthetic polymer which is capable of effectively reducing water loss filtering from the slurry to porous formation during cementing process.
  • Specially designed for lightweight cement slurry system and normal density cement slurry with strong dispersity.
  • Generate thickening effect on cement slurry, enhance its suspension stability and prevent sedimentation.
  • The lightweight cement slurries applied with FLA CG212 products exhibit good thickening performance. 
  • Fast compressive strength development of set cement.
  • Applicable mixing water: from fresh water to half-saturated salt water.
  • Used below temperature of 180℃(356℉, BHCT).
  • Compatible with other additives.
  • CG212 series contains of L-type liquid, L-A type anti-freezing liquid and S-P type powder.
  • Recommended dosage is 2.0-6.0 (BWOC) for liquid products, and 0.6-2.5% (BWOC) for powder product.

 

PHYSICAL AND CHEMICAL INDICATORS

CG212S-P

CG212L

Appearance:White or faint yellow powder

Appearance:Colorless or faint yellow liquid

Bulk Density, g/cm3: 0.80±0.20

Density, g/cm3: 1.10±0.05(L), 1.15±0.05(L-A)

Water-Solubility: Soluble

Water-Solubility: Soluble


CEMENT SLURRY PERFORMANCE 

Item

Test Condition

Technical Indicator

Density of the lightweight cement slurry, g/cm3

25℃, Atmospheric Pressure

1.35±0.01

Fluid loss,ml

Fresh water system

80℃,6.9MPa

≤80

Thickening performance

Initial consistency, Bc

80℃/45min,46.5MPa

≤30

40-100 Bc thickening time, min

≤40

Free fluid, %

80℃, Atmospheric Pressure

≤1.4

24h compressive strength, MPa

Lightweight cement slurry

≥5.0


PACKING AND STORAGE

  • The liquid type products should be used within 12 months after production. Packed in 25kg, 200L and 5 US gallon plastic barrels.The powder type products should be used within 24 months after production. Packed in25kg bag.
  • Customized packages are also available.
  • Once expired, it shall be tested before use.


                 Keiloil·Global Factory-www.kelioil.com/en

MSDS

Click here to download MSDS

SECTION 1: PRODUCT NAME

PRODUCT NAME: CG212 Cementing Fluid loss additive

SECTION 2: HAZARDS IDENTIFICATION

CHARACTERISTICS: Nonflammable and inexplosive.

HEALTH HAZARDS: Irritate eye and skin slightly; Cause irritation of the mucosal and upper respiratory tract.

ENVIROMENTAL HAZARDS: Slightly toxic to fish and animal.

SPECIAL ATTENTION: None.

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS

Type

INGREDIENT NAME

COMPOSITION

CAS NO.

CG212L

Copolymer

20-30%

/

Water

70-80%

7732-18-5

CG212S-P

Copolymer

98%

/

Water

2%

7732-18-5

SECTION 4: FIRST AID MEASURES

SKIN CONTACT: Put off contaminated clothing, rinse with soapy and clean flowing water.

EYE CONTACT: Raise the eyelid. Rinse it with plenty of clean flowing water and physiological saline. Consult a doctor if irritation occurs.

INGESTION: Drink plenty of water to induce vomiting; If be uncomfortable, consult a doctor please.

INHALATION: Escape to fresh air; If have breathing difficulties, consult a doctor.

SPECIAL ATTENTION: None.

SECTION 5: FIRE-FIGHTING MEASURES

FLAMMABILITY: See section 9(Physical and Chemical Properties).

FIRE FIGHTING MEDIUM: Foam, dry powder, carbon dioxide, water.  

SPECIAL FIRE-FIGHTING EQUIPMENTS: None.

SECTION 6: ACCIDENTAL RELEASE MEASURES

PERSONAL PRECATIONALS: Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection).

SPILL: Collect the most of leakage, clean the site of leakage.

WASTE TREATMENT METHODS: Be properly buried or handled according to local environment requirement.

PACKING TREATMENT METHODS: Transferred to the dumping site for proper disposal.

SECTION 7: HANDLING AND STORAGE

HANDLING: Keep the containers closed when not in use. Do not get in eyes, on skin. Wear proper personal protection.

STORAGE ATTENTION: Stored in a dry cool place, prevented from the sun and rain, kept away from the heat and fire and incompatible materials.

SPECIAL ATTENTION: None.

SECTION 8: ESPOSURE CONTROLS AND PERSONAL PROTECTION

ENGINEERING CONTROL: Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors or particles below their respective threshold limit value.

RESPIRATORY PROTECTION: Wear dusk mask.

SKIN PROTECTION: Wear standard protective clothing and gloves.

EYE PROTECTION: Wear chemical splash goggles.

SPECIAL ATTENTION: Smoking, food and water drinking are all forbidden. 

SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES

Item

CG212L-A

CG212S-P

COLOR

White or faint yellow

White or faint yellow

PHYSICAL STATE

Liquid

powder

RELATIVE DENSITY(water equal to 1)

Standard type1.10±0.05

Anti-freeze type1.15±0.05

——

BULK DENSITY, g/cm3

——

0.80±0.20

ODOR

Slightly pungent

Slightly pungent

WATER SOLUBILITY

Soluble in water

Soluble in water

SECTION 10: STABILITY AND REACTIVITY

AVIOD: Open fire, High temperature.

INCOMPATIBLE MATERIAL: Strong oxidizers.

HAZARDOUS DECOMPOSITION PRODUCTS: None.

SECTION 11: TOXICOLOGICAL INFORMATION

INVASIVE ROUTE: Accidental inhalation or ingestion.

HEALTH HAZARD: Careless ingestion has a stimulating effect on the oral cavity and stomach.

SKIN CONTACT: Contact with skin for a long time, slightly induce skin redness.

EYE CONTACT: Induce eye irritant.

INGESTION: Lead to nausea and vomiting.

INHALATION: Lead to cough and prickle.

CARCINOGENICITY: None.

SPECIAL REMIND: None.

SECTION 12: ECOLOGICAL INFORMATION

BIODEGRADABLE: Not available.

ECOTOXICITY: Not available.

SECTION 13: DISPOSAL CONSIDERATIONS

WASTE TREATMENT METHOD: Be properly buried or handled according to local environment requirement.

PACKING TREATMENT METHOD: Transferred to the dumping site for proper disposal.

SECTION 14: TRANSPORT INFORMATION

This product is not included in the dangerous goods transport international regulations(IMDG,IATA,ADR/RID)

PACKAGE       Liquid-Plastic barrel, Powder-bag.

SECTION 15: REGULATORY INFORMATION

The Management Regulations of Dangerous Chemicals Management

The Practical Detailed Rules and Regulation for Dangerous Chemicals Management

The Classification and mark of Common Chemical Products (GB 13690-2009)

The General Rule of Common Chemical Products (GB15603-1995)

The Technology Conditions for the Packing Marks for Hazardous Cargo (GB 12463 -1990)

SECTION 16: OTHER INFORMATION

RELEASE DATE: 12/18/2014.

REVISION DATE: 10/14/2022.

SUGGEST FOR AND USED RESTRICTIONS: The product is to be used in applications consistent with our product literature. This product is applied to industry only.

 

 


CG212 Anti-settling Fluid Loss Additives
CG212 is suitable for low-density or conventional-density cement slurry systems with strong dispersibility, especially for 1.2~1.6g/cm³ low-density cement slurry.
It has a significant thickening effect on cement slurry, effectively enhancing the suspension stability of the cement slurry system and preventing sedimentation.
The low-density cement slurry system has good thickening performance and good cement stone strength development.
Long press to look detail
Long by picture save/share

CG212 Anti-settling Fluid Loss Additives

INQUIRY

在线询盘 MORE+
  • 联系人 *

  • 手机 *

  • 描述

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully
请双击输入内容...

Related Products

Leave Us a Message

Fill blanks to contact our sales team.

  • Company Name

  • Name

  • Mobile

  • E-mail *

  • Verification Code

  • Message

  • Send

  • Security Code
    Refresh the code
    Cancel
    Confirm
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了